GVC1 GREEN 3451

S GO386
GOTHAM

Construction 

Jacket:Polyofine FRNC Ø 4.5 mm green RAL 6018

Shield No. 1:Braiding with tinned copper wire (0.10 mm)
Coverage min. 91%

Shield No. 2:

Aluminium foil

Insulation:Foam-PE Ø 2.80 mm

Conductor:Solid bare copper wire 0.60 mm

 

Technical specifications

Inner conductor resistance:61 Ohm/km

Outer conductor resistance:17 Ohm/km

Screening efficiency:> 90dB

Attenuation:

at 1 MHz < 1.3 dB/100m

at 3.6 MHz < 2.6 dB/100m

at 10 MHz < 3.9 dB/100m

at 71.5 MHz < 10.4 dB/100m

at 135 MHz < 12.8 dB/100m

at 180 MHz < 14.6 dB/100m

at 270 MHz < 17.9 dB/100m

at 360 MHz < 20.6 dB/100m

at 540 MHz < 25.7 dB/100m

at 720 MHz < 31.6 dB/100m

at 1000 MHz < 34.9 dB/100m

at 1500 MHz < 43.5 dB/100m

at 2250 MHz < 53.1 dB/100m

Insulation resistance:> 10 gohm/km

Capacitance:< 56 nF/km

Characteristic Impedance:

200 MHz:75 +/- 2 ohm

Temperature range:

 flexi-installed:-5° to +50° C

 fix-installed:-30° to +70° C

Return Loss (RL):> 20dB up to 2.25 GHz

Digital frequency data transmission distances :

 SMPTE 259M composite NTSC

143 Mb/s 288m (max.)

ITU-R BT. 601 compsoite PAL

177 Mb/s 256m (max.)

SMPTE 259M component video

270 Mb/s234m (max.)

SMPTE 259M compressed HDTV

360 Mb/s 205m (max.)

SMPTE 344M compressed HDTV

540 Mb/s 167m (max.)

SMPTE 292M HDTV

1485 Mb/s 61m (max.)

!
 <<